Protein Chemistry

🧬 1. How Do We Determine Protein Primary Structure?

First choice: DNA databases

Today, we usually determine protein sequence from:

  1. Genome / cDNA databases
  2. Translate DNA → protein sequence

But this does not reveal:

  • Post-translational modifications (PTMs)
  • Processing events (cleavages, signal peptides removed)

When DNA info is missing or incomplete → we must determine sequence experimentally.


✂️ 2. Protein Digestion: Why Do We Cut Proteins?

Large proteins are too big to sequence directly. So we:

  1. Digest into smaller peptides
  2. Separate peptides (HPLC)
  3. Sequence peptides (Edman or MS)
  4. Reconstruct full sequence

🔪 Enzymatic Cleavage (Very Important)

Each protease cuts at specific residues:

EnzymeCleaves
TrypsinAfter Lys (K) & Arg (R)
ChymotrypsinAfter Phe (F), Trp (W), Tyr (Y)
V8 proteaseAfter Asp (D), Glu (E)
Asp-NBefore Asp
ThermolysinBefore large hydrophobic residues

Also chemical cleavage:

  • CNBr → after Met
  • Mild acid → Asp–Pro
  • Hydroxylamine → Asn–Gly

These different cleavage patterns are crucial for determining sequence order.


🧪 3. Edman Degradation (Stepwise N-terminal sequencing)

How it works

  1. Label N-terminal amino acid with phenyl isothiocyanate (PITC)
  2. Cleave off labeled amino acid
  3. Identify it by reverse-phase HPLC
  4. Repeat cycle

❗ Why can we only sequence ~10 amino acids?

You asked:

Edman only sequences few AA because labeling is not 100% degraded?

Yes — correct, and here is the full explanation:

Each cycle is ~99% efficient (example).

Cycle 1:

  • 99% correct removal
  • 1% remains uncleaved

Cycle 2:

  • Now mixture contains:
    • Mostly second AA
    • 1% leftover from first cycle

Cycle 3:

  • Even more mixture

After many rounds:

  • Signal becomes too noisy
  • Peaks overlap
  • Sequence becomes ambiguous

So we can only reliably sequence ~10 residues.

This is cumulative inefficiency.


🔁 4. Why Use Trypsin AND Chymotrypsin?

You asked:

To know the order, do we use trypsin & chymotrypsin?

Yes — this is essential logic.

If we digest only with trypsin:

Example fragments:

A - B - C - K D - E - F - R G - H - I - K

We don’t know their order in full protein.

Now digest same protein with chymotrypsin:

Different fragments:

C - K - D F - R - G I - K - J

Now we find overlaps:

  • Fragment 1 overlaps with fragment 2
  • Like solving a puzzle

This is called overlapping peptide mapping.

Without two different digestions → cannot reconstruct full order.

This applies to BOTH:

  • Edman sequencing
  • Mass spectrometry

⚡ 5. Tandem Mass Spectrometry (MS/MS)

Modern method of choice.

Step 1 – Ionization

Two soft ionization methods:

🟢 MALDI-TOF

Matrix Assisted Laser Desorption Ionization Usually produces:

  • Mostly singly charged ions (+1)
  • Sometimes +2

🔵 ESI (Electrospray Ionization)

Sprays protein into charged droplets.

Produces:

  • Multiple charge states (+5, +10, +20…)
  • One molecule can carry many charges

❓ Why does ESI produce more charges than MALDI?

Because:

  • MALDI → desorption event usually creates single protonation
  • ESI → droplet evaporation leaves many protons on protein surface
  • Large proteins expose many basic residues
  • More sites → more protonation

So ESI gives a charge distribution spectrum.


🧩 6. Tandem MS: How Sequence Is Determined

MS1:

Measure mass of intact peptide.

Collision Cell:

Peptide fragmented.

MS2:

Measure masses of fragments.


💥 Peptide Fragmentation

Fragmentation happens at peptide backbone.

Main ions:

Fragment TypeBreaks atName
b-ionN-terminal fragment
y-ionC-terminal fragment
c-ionN-side different bond
z+1-ionC-side different bond

Most common in CID:

  • b-ions
  • y-ions

How sequence is read

If peptide is:

A–B–C–D–E

You get:

  • b1 (A)
  • b2 (A–B)
  • b3 (A–B–C)
  • etc.

Differences between peaks correspond to one amino acid mass.

So sequence is deduced by: Mass difference between consecutive fragments.


❗ 7. Can MS Distinguish Lysine and Isoleucine?

You asked:

MS can't determine lysine and isoleucine because masses are same?

Correction:

It is Leucine (L) and Isoleucine (I) that have identical mass.

Both:

  • Same elemental composition
  • Same molecular weight
  • Structural isomers

Mass spectrometry cannot distinguish them by mass alone.

However:

  • HPLC separation can sometimes distinguish due to structural differences.
  • Advanced MS fragmentation methods sometimes help.

But classical MS → cannot distinguish L and I.


📏 8. Protein Size Determination Methods

1️⃣ SDS-PAGE

  • SDS denatures proteins
  • Coats protein with negative charge
  • ~1 SDS per 2 amino acids
  • Mobility depends mainly on size

Smaller proteins → move faster.

Used for 1–200 kDa.


2️⃣ Mass Spectrometry

Most accurate molecular weight method.

Can detect:

  • Monomers
  • Dimers
  • Multiple charge states

3️⃣ Size Exclusion Chromatography (SEC)

You asked:

Smaller molecules have longer travel time? Why?

Yes — and this is correct.

Column contains porous beads.

Large proteins:

  • Cannot enter pores
  • Travel straight through
  • Elute earlier

Small proteins:

  • Enter pores
  • Take longer path
  • Elute later

So:

SizeElution Time
LargeShort
SmallLong

Separation based on hydrodynamic radius.


⚖️ 9. Comparison of Methods

MethodAccuracySize RangeNotes
SDS-PAGEModerate1–200 kDaVery common
SECLower accuracyUp to 10,000 kDaGood for complexes
UltracentrifugationGoodLarge complexesRarely used today
Mass SpectrometryVery highDependsBest for exact MW

🔬 10. Post-Translational Modifications (PTMs)

Mass spectrometry can detect:

  • Phosphorylation
  • Glycosylation
  • Other modifications

Because: Fragment masses shift according to modification.

DNA sequencing cannot detect PTMs.


🧠 Final Big Picture

To determine protein sequence experimentally:

  1. Digest protein
  2. Separate peptides (HPLC)
  3. Ionize (ESI or MALDI)
  4. MS1 → select peptide
  5. Fragment in collision cell
  6. MS2 → read b/y ion ladder
  7. Repeat with different protease
  8. Align overlapping fragments

🔎 Summary of Your Specific Questions

✔ Edman limited due to cumulative inefficiency ✔ Two proteases needed for overlap mapping ✔ Tandem MS determines sequence via fragment mass differences ✔ MS cannot distinguish Leu/Ile by mass ✔ b, y, c, z+1 ions result from backbone cleavage ✔ ESI produces multiple charge states due to droplet protonation ✔ SEC: small molecules take longer because they enter pores

Quiz

Score: 0/30 (0%)